  • PG4 165 ROBUST ALU CAROUSEL

Image displayed may not be the exact size or body/pod colour (where applicable) of the luminaire and so is indicative only.

Pleiad G4 165 Robust

FG-73050-0-RW

PLEIAD G4 165 ROBUST Recessed Downlight 1177lm 10W LED Wide beam 4000K/Ra90+ 240V Matt reflector Non-dim Class II Std AUS f&p 2.0m Dia:230mm H:125mm IP64/20 IK10/20J White. Supplied as: EL-73050.0-0-RW + EL-99473-0

Custom Datasheet

Optional: Enter your details for the document header

Local manufacture
Fagerhult Logo 60px

Pleiad G4 165 Robust

FG-73050-0-RW

PLEIAD G4 165 ROBUST Recessed Downlight 1177lm 10W LED Wide beam 4000K/Ra90+ 240V Matt reflector Non-dim Class II Std AUS f&p 2.0m Dia:230mm H:125mm IP64/20 IK10/20J White. Supplied as: EL-73050.0-0-RW + EL-99473-0

Eagle Lighting
PG4 165 ROBUST ALU CAROUSEL

  • Technical Overview

    PG4 Robust Dimensional Drawing
    • Finish
      White
    • L = Length [mm]
      -
    • W = Width/Diameter [mm]
      230
    • H = Height [mm]
      125
    • CL = Recessing Length [mm]
      -
    • CW = Recessing Width/Diameter [mm]
      205
    • Weight [kg]
      1.3
    Normalised Polar Curve [cd/klm]

    • Finish
      White
    • L = Length [mm]
      -
    • W = Width/Diameter [mm]
      230
    • H = Height [mm]
      125
    • CL = Recessing Length [mm]
      -
    • CW = Recessing Width/Diameter [mm]
      205
    • Weight [kg]
      1.3
    PG4 Robust Dimensional Drawing
    Normalised Polar Curve [cd/klm]

  • Photometric Values

    • Control Type
      Non-dim
    • Ceiling Type/Mounting
      Recessed
    • Wattage [W]
      10
    • CLO Enabled
      No
    • Final Wattage CLO [W]
      10
    • System Lumens [lm]
      1177
    • Luminaire Lumens [lm]
      1108
    • Efficacy [lm/W]
      111
    • Lighting Type
      Direct
    • Target Spacing [m]
      -
    • Target H Illuminance [lux]
      -
    • LPD [W/m2]
      -
    • NPD [W/sqm/100lux]
      -
    • Beamwidth (FWHM)
      -
    • Optics Type
      Matt reflector
    • UGR
      -
  • Emergency Parameters

    • Emergency Type
      -
    • Emergency Class
      -
  • Colour Quality

    • CCT [K]
      4000K
    • CCT1 [K]
      4000K
    • CCT2 [K]
      -
    • Other Light Colour
      -
    • CRI
      Ra90+
    • COI Compliance
      Compliant
    • CLA 2.0
      -
    • M-DER
      -
    • R9
      54
    • Melanopic Ratio
      0.7
    • Circadian Stimulus CS [%]
      -
    • Circadian Light [lux]
      -
    • TM-30 RF
      89
    • TM-30 RG
      96
    • M-EDI
      -
  • Lifetime and Miscellaneous Parameters

    • LM80 Test Duration [hrs]
      11,088
    • L90B50 Lifetime [hrs]
      >61000
    • TM21 L70 Reported Lifetime [hrs]
      >61000
    • L100B50 Lifetime (CLO) [hrs]
      -
    • TM21 L90 Reported Lifetime [hrs]
      >61000
    • SDCM Initial
      3
  • Downloads